2 - Example of a Sysex configuration of an eo•body preset
The whole sysex file has to be sent at one time
To modify parameters, values from row 3 for the switches, from row 4 for the
potentiometers, from row 6 to 23 for imputs 1 to 16 need to be adjusted.
0, ‘eoprogram ‘; program name
(for internal use of the editor only)
1, 240 0 32 57 64 127; header tag (not to be changed)
2, 0 8 0 0; empty informations for further use
3, 1 0 1 0 1 0 2 0 1 0 3 0 1 0 4 0; switch configuration
4, 1 0 5 0 1 0 6 0 1 0 7 0; potentiometer configuration
5, 0 0; empty informations for further use (not to be changed)
6, 0 0 8 0 0 8 1 0 0 0 0 0 3 0 0 0 0 0; input 1 configuration
7, 0 0 8 0 0 8 2 0 0 0 0 0 3 0 0 0 0 0; input 2 configuration
8, 0 0 8 0 0 8 3 0 0 0 0 0 3 0 0 0 0 0; input 3 configuration
9, 0 0 8 0 0 8 4 0 0 0 0 0 3 0 0 0 0 0; input 4 configuration
10, 0 0 8 0 0 8 5 0 0 0 0 0 3 0 0 0 0 0; input 5 configuration
11, 0 0 8 0 0 8 6 0 0 0 0 0 3 0 0 0 0 0; input 6 configuration
12, 0 0 8 0 0 8 7 0 0 0 0 0 3 0 0 0 0 0; input 7 configuration
13, 0 0 8 0 0 8 8 0 0 0 0 0 3 0 0 0 0 0; input 8 configuration
14, 0 0 8 0 0 8 9 0 0 0 0 0 3 0 0 0 0 0; input 9 configuration
15, 0 0 8 0 0 8 10 0 0 0 0 0 3 0 0 0 0 0; input 10 configuration
16, 0 0 8 0 0 8 11 0 0 0 0 0 3 0 0 0 0 0; input 11 configuration
17, 0 0 8 0 0 8 12 0 0 0 0 0 3 0 0 0 0 0; input 12 configuration
18, 0 0 8 0 0 8 13 0 0 0 0 0 3 0 0 0 0 0; input 13 configuration
19, 0 0 8 0 0 8 14 0 0 0 0 0 3 0 0 0 0 0; input 14 configuration
20, 0 0 8 0 0 8 15 0 0 0 0 0 3 0 0 0 0 0; input 15 configuration
21, 0 0 8 0 0 8 0 1 0 0 0 0 3 0 0 0 0 0; input 16 configuration
22, 247; Footer tag
(not to be changed)
Switches and potentiometers use the same parameters
Switch configuration 4 x 2 bytes for switches A, B, C, D
Potentiometer configuration 3 x 2 bytes for potentiometers 1, 2, 3
channel C (0-15, type of information X (0-5), value 0 0 (0-127, in 8 bits on 2 bytes)
C X 0 0
Example:
Controller 1 on Channel 1: 0 0 1 0
Controller 64 on Channel 16: 15 0 0 4
Type of information
0CC
1 Note On Trigger
2 Program Change
3 Picht Bend
4 Polyphonic After Touch
5 Monophonic After Touch
An entire sequence for pots will be
Example CC 1 to 3 on Channel 1
4, 0 0 1 0 0 0 2 0 0 0 3 0;